Skip to Content
Services
Vibration Analysis
Dynamic Balancing
Laser Alignment
Thermography
Mechanical Repair
Products
Blog
Contact
PFE Limited
0
0
Services
Vibration Analysis
Dynamic Balancing
Laser Alignment
Thermography
Mechanical Repair
Products
Blog
Contact
PFE Limited
0
0
Folder: Services
Back
Vibration Analysis
Dynamic Balancing
Laser Alignment
Thermography
Mechanical Repair
Products
Blog
Contact
Accelerometers & Vibration Hardware SC310/SC311 | USB Configurable, Single Band Vibration / Ultrasound Plus Temperature Signal Conditioner
SC310_750.jpg Image 1 of
SC310_750.jpg
SC310_750.jpg

SC310/SC311 | USB Configurable, Single Band Vibration / Ultrasound Plus Temperature Signal Conditioner

£0.00

Available for use with proximity probe drivers, standard CTC accelerometers & TA200 series, or TA900 Series hazardous rated sensors.

Micro USB port and dedicated software allow for field configuration of input signal, scale values, filtering options and outputs; built-in IEPE supply for powering sensors can be toggled on or off configurations. **USB Configurator Cord Sold Separately

Provides process control signals to a PLC, DCS, or SCADA system that are proportional to the vibration levels set within the signal conditioner.

  • Accepts a variety of signal inputs: acceleration, velocity, temperature and displacement; capable of monitoring ultrasound frequency signals up to 40 kHz

  • Provides a user selectable band-pass filtered output from one single axis sensor input

  • An additional built-in temperature output is a standard supplied feature, which may be utilized when using a CTC TA200 series dual output vibration and temperature sensor

Standard ISO 10816-3 configurations are available for accelerometers/velocity input only, and not for proximity probes driver inputs. Please specify your requirements in quotation comments for proximity probe driver inputs, or custom accelerometer settings. Alternatively the settings can be easily altered with the USB interface and free software.

Input:
Config:
Quantity:
Add To Cart

Available for use with proximity probe drivers, standard CTC accelerometers & TA200 series, or TA900 Series hazardous rated sensors.

Micro USB port and dedicated software allow for field configuration of input signal, scale values, filtering options and outputs; built-in IEPE supply for powering sensors can be toggled on or off configurations. **USB Configurator Cord Sold Separately

Provides process control signals to a PLC, DCS, or SCADA system that are proportional to the vibration levels set within the signal conditioner.

  • Accepts a variety of signal inputs: acceleration, velocity, temperature and displacement; capable of monitoring ultrasound frequency signals up to 40 kHz

  • Provides a user selectable band-pass filtered output from one single axis sensor input

  • An additional built-in temperature output is a standard supplied feature, which may be utilized when using a CTC TA200 series dual output vibration and temperature sensor

Standard ISO 10816-3 configurations are available for accelerometers/velocity input only, and not for proximity probes driver inputs. Please specify your requirements in quotation comments for proximity probe driver inputs, or custom accelerometer settings. Alternatively the settings can be easily altered with the USB interface and free software.

Available for use with proximity probe drivers, standard CTC accelerometers & TA200 series, or TA900 Series hazardous rated sensors.

Micro USB port and dedicated software allow for field configuration of input signal, scale values, filtering options and outputs; built-in IEPE supply for powering sensors can be toggled on or off configurations. **USB Configurator Cord Sold Separately

Provides process control signals to a PLC, DCS, or SCADA system that are proportional to the vibration levels set within the signal conditioner.

  • Accepts a variety of signal inputs: acceleration, velocity, temperature and displacement; capable of monitoring ultrasound frequency signals up to 40 kHz

  • Provides a user selectable band-pass filtered output from one single axis sensor input

  • An additional built-in temperature output is a standard supplied feature, which may be utilized when using a CTC TA200 series dual output vibration and temperature sensor

Standard ISO 10816-3 configurations are available for accelerometers/velocity input only, and not for proximity probes driver inputs. Please specify your requirements in quotation comments for proximity probe driver inputs, or custom accelerometer settings. Alternatively the settings can be easily altered with the USB interface and free software.

Datasheet

PFE Limited

Unit C Maritime Business Park
Dock Road
Wirral
CH41 1AQ
United Kingdom

(+44) 0151 512 2130
enquiries@pfelimited.com

©Paul Ford Engineering Limited

Registration Number: 05621242
VAT Number: GB874507501

ISO9001 Badge, Certificate 247044

Certificate Number: 247044
Check validity here.

Certificate Number: IA0155

Quote Request
Please provide your contact details , and we will provide a quotation in response.
Our sales are business to business (B2B) only, which includes educational institutes. We do not sell directly to consumer (B2C).
Name *
Location *
Please note we do not currently sell outside of the UK & Ireland region.
For shipping calculation purposes, full address will be requested on quotation acceptance.
Desired Currency *
Please note duty & taxes will be covered for locations inside of the United Kingdom only, regardless of currency. Those in Ireland will be liable to import duty and/or VAT.
Please ensure your email address is correct before submitting.
*
Further details on your product selection, or general comments:

Thank you for your quotation request, we will be in touch as soon as possible.